CIC-D100 Laboratory Ion Chromatography

CIC-D100 ion chromatograph is a classic product, which has been accepted by many customers based on the latest requirement of users, a newly upgrade CIC-100 for enventional detection came into being. The new IC not only can detect anions, cations and other polar substances in different matrix samples, but also separate ions with 4 orders of magnitude difference. Compared with the previous one, it is more accurate and reliable. One key switch and intelligent maintenance functions are added to give users a better experience. It is suitable for third-party testing institutions, enterprises, environmental protection, chemical industry, mining and metallurgy and other fields.

分类: 标签:

描述

CIC-D100 ion chromatograph is a classic product, which has been accepted by many customers based on the latest requirement of users, a newly upgrade CIC-100 for enventional detection came into being. The new IC not only can detect anions, cations and other polar substances in different matrix samples, but also separate ions with 4 orders of magnitude difference. Compared with the previous one, it is more accurate and reliable. One key switch and intelligent maintenance functions are added to give users a better experience. It is suitable for third-party testing institutions, enterprises, environmental protection, chemical industry, mining and metallurgy and other fields.

 

Technology Advantage:

  • Auto-range Conductivity Detector
  • It can directly detect the signal from ppb to ppm concentration without adjusting the range;
  • Eluate Preheating
  • By keeping the temperature of the eluate entering the column constant to ensure data stability;
  • Intelligent Switch
  • Just click once to complete the startup parameter setting and shutdown operation;
  • Multiple detectors available
  • Standard: conductivity detector
  • Optional: ampere, UV, mass spectrometer and other detectors.

Technology Parameter:

Pump

Maximum Pressure:42MPa(Stainless steel)

Flow Rate Range:0.001~9.999mL/min

Injector

Maximum Pressure: 35MPa

External Diameter of The Tube: 1/16″

Conductivity Detector   

Cell Volume:≤0.8μL

Detection Range:0~35000μS/cm

Baseline Noise:≤0.001μS/cm

Baseline Drift:≤0.02μS

Temperature Range: RT+5-60℃(41-140℃F)

Maximum Pressure: 10.0MPa

Others:

Power Requirements:150W

Dimensions(L*W*H*):310*430*530 (mm)

Net Weight(KGS):22

Gross Weight(KGS):29

其他信息

Pump Maximum Pressure

42MPa(Stainless steel)

Flow Rate Range

0.001~9.999mL/min

Injector Maximum Pressure

35MPa

External Diameter of The Tube

1/16"

Conductivity Detector Cell Volume

≤0.8μL

Detection Range

0~35000μS/cm

Temperature Range

RT+5-60℃(41-140℃F)