AA-1800H Atomic Absorption Spectrophotometer (AAS)

AA-1800H atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis.

分类: 标签:

描述

AA-1800H atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis.

AA-1800H atomic absorption spectrophotometer is now widely used in scientific research, quality control, disease control, environmental protection, metallurgy, agriculture, chemical industry .Hardware and software design of innovation to ensure the accuracy, safety, ease of use in the analysis of samples, equipment maintenance, simple and convenient.

Main features

High precision automatic optical system:

1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of analysis. Automatic 6 socket configuration six independent lamp power supply, can be respectively preheating

Polymer spray chamber:

Polymer materials corrosion spray chamber, acid and alkali resistance, includinghydrofluoric acid, either organic or inorganic solution can be the highest sensitivity andstability

Titanium burner:

Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type, corrosion resistant, resistant to high salt, greatly improve the analysis efficiency andaccuracy of the flame

Automatic analysis:

It can automatically accomplish safety ignition, extinction and switching, reliable structure, low fault rate, thus ensuring the sensitivity and reproducibility of the flame method.

The light source system six lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic adjustment of the power supply parameters and the beam position, automaticwavelength scanning and searching peak.

Software function:

High intelligent software, powerful function, friendly interface English operation. Automatic instruments and additional control, flame, graphite furnace operating mode can be switched automatically, automatic optimization, automatic dilution; mouse operation, automatic setup menu data and correction method.

Graphite furnace temperature control:

Gas dual temperature control inside and outside, 20 order linear or nonlinear heating, to ensure that the measured elements has the highest sensitivity; furnaceenriched up to 20 times, the longitudinal optically monitoring the graphite tube wall temperature, maximum temperature to 3000 degrees centigrade.

High technology index:

AA-1800 atomic absorption spectrophotometer elements testsensitivity meet international best level, sensitivity of less than or equal to0.015μg/mL/1%; baseline drift is less than 0.003Abs/30m, the stability is better than 0.005Abs/4h.

Background correction system:

Using deuterium hollow cathode lamp advanced and self absorption background deduction of background correction, to eliminate the interference of molecular absorption of low content determination, reducing the noise emission of deuterium lampand prolongs the service life, has excellent stability. Deuterium lamp background signalfor 1A, background correction ability > 50 times.

Intelligent analysis:

Greart intelligence, humanized design, flame and graphite furnace atomizer automatic switching, automatic optimization of graphite furnace atomizer, automatically set the flame height adjustment, automatic ignition, automatic optimization of the horizontal position, system automatically sets the gas flow. In the case of power failure, misoperation, acetylene leakage, the system will automatically start the safetyprotection function.

Automatic sampler:

Integrative design of graphite furnace, using high precision syringe, lowest in 0.5μl samples, with intelligent online dilution and concentration function.

 

Technical parameters:

Mainframe

Model:AA-1800H

Light Source:≤6 lamps automatic turret, automatic alignment

Power Supply:110/220V (+5% ~ -10%), 60/50Hz; 5000VA

Lamp Current: pulsed power supply

Optical System: large 1800 /mm grating ruling, full closed optical system

Wavelength Range:190nm-900nm,Automatically peak find, a key optical optimization function                        Wavelength Accuracy:≤0.15nm

Wavelength Repeatability:±0.1nm

Spectral Bandwidth:0.1nm、0.2nm、0.4nm、1.0nm、2.0nm

(5 steps with automatic changeover)

Baseline Stability:≤±0.002A/30 min (Static) ≤±0.005A/30min (Dynamic)

Absorbance Range:0-4A

Flame Analytical System

Detector: imported photomultiplier tube

Burner Head: full titanium combustion head, 50mm or 100mm general combustion head

Atomization Chamber: polymer explosion-proof spray chamber

Nebulizer: atomizer efficient glass atomizer, can also be customized

Ignition Type: microcomputer control, automatic ignition

Gas Control: automatic gas control system

Detection Limits(Cu):0.002μg/mL

Precision:RSD≤0.5%

Graphite Furnace Analytical System

Heating Mode: vertical heating

Temperature Control Method: vertical optical temperature monitoring graphite tube wall temperature

Temperature Range: room temperature to 3000℃

The Program: automatic temperature control up to 20 order

Temperature Control: the furnace enriched up to 20 times

Characteristics Volume:0.5 × 10-12g (Cd)

Detection Limit:0.4 × 10-12g (Cd)

Precision: RSD≤3%

The Cooling Water: can choose cooling water circulation system

Safety: the graphite tube damage, water flow

air pressure and other alarm temperature overheating protection

Autosampler Graphite Furnace

Sample Tray:70 sample cups, 6 reagent cup

Sample Volume:1-100μl

The Smallest Lincrement:0.1 μl

The Volume of Sample Repeatability Volume: better than 1%(at the time of 10mL-100mL)

Repeated Sampling Frequency: up to 99 Times

Cleaning and Waste: each 500mL

Container Volume

其他信息

Light Source

≤6 lamps automatic turret, automatic alignment

Optical System

large 1800 /mm grating ruling, full closed optical system

Wavelength Range

Wavelength Range

Wavelength Accuracy

≤0.15nm

Wavelength Repeatability

±0.1nm

Spectral Bandwidth

0.1nm、0.2nm、0.4nm、1.0nm、2.0nm
(5 steps with automatic changeover)

评价

目前还没有评价

成为第一个“AA-1800H Atomic Absorption Spectrophotometer (AAS)” 的评价者

您的电子邮箱地址不会被公开。 必填项已用 * 标注

发表评论