Flash Point Tester Series

搜索结果 8:

SYD-261 Pensky-Martens Closed-Cup Flash Point Tester

SYD-261 Pensky-Martens Closed-Cup Flash Point Tester

This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point – Pensky-Martens Closed Cup Method and ASTM D93 Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.

SYD-261-1 Pensky-Martens Closed-Cup Flash Point Tester

SYD-261-1 Pensky-Martens Closed-Cup Flash Point Tester

This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point – Pensky-Martens closed cup method and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.

SYD-261D Automatic Pensky-Martens Closed-Cup Flash Point Tester

SYD-261D Automatic Pensky-Martens Closed-Cup Flash Point Tester

This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point – Pensky-Martens closed cup method and ASTM D93 Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.

SYD-3536 Cleveland Open-Cup Flash Point Tester

SYD-3536 Cleveland Open-Cup Flash Point Tester

This instrument is designed and made as per standards GB/T3536-2008 Petroleum Products – Determination of Flash and Fire Points – Cleveland Open Cup Method and ASTM D 92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester. It is applicable to all petroleum products with flash points and fire points above 79℃ except fuel oils.

SYD-3536-1 Cleveland Open Cup Flash Point Tester

SYD-3536-1 Cleveland Open Cup Flash Point Tester

This instrument is designed and made as per GB/T3536-2008 Petroleum Products – Determination of Flash and Fire Points – Cleveland open cup method and ASTM D 92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester. It is applicable to all petroleum products with flash points above 79℃ and below 400℃ except fuel oils.

SYD-3536D Automatic Cleveland Open Cup Flash Point Tester

SYD-3536D Automatic Cleveland Open Cup Flash Point Tester

This instrument is designed and made as per GB/T3536-2008 Petroleum Products – Determination of Flash and Fire Points – Cleveland open cup method and ASTM D 92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester. It is applicable to all petroleum products with flash points above 79℃ and below 400℃ .

SYD-5208 Rapid Low Temperature Closed Cup Flash Point Tester

SYD-5208 Rapid Low Temperature Closed Cup Flash Point Tester

This instrument is designed and made as per GB/T 5208-2008 Determination of flash point – Rapid equilibrium closed cup method. It can meet the requirements of rapid determination for closed cup flash point of petroleum products in oil,chemical, varnish, paint, railway, aviation, electricity, commercial inspection and science research institution.
This instrument is specially suitable to determine different kinds of colored paints,oil paints, adhesives,solvents and petroleum products which the closed cup flash point is -30℃~50℃.The instrument is also correspond with ISO1523 and ISO3679.

SYD-5208D Rapid Low Temperature Closed Cup Flash Point Tester

SYD-5208D Rapid Low Temperature Closed Cup Flash Point Tester

This instrument is designed and made as per GB/T 5208-2008 Determination of flash point – Rapid equilibrium closed cup method. It can meet the requirements of rapid determination for closed cup flash point of petroleum products in oil,chemical, varnish, paint, railway, aviation, electricity, commercial inspection and science research institution.
This instrument is specially suitable to determine different kinds of colored paints,oil paints, adhesives,solvents and petroleum products which the closed cup flash point is 0℃~100℃.The instrument is also correspond with ISO1523 and ISO3679.