If your lab is focused on water quality analysis, then you will need many electrochemical instruments.
The pH meter helps you detect the pH of the solution.
A conductivity meter is used to estimate the total or salt content of ions in water.
The dissolved oxygen meter is used to measure the oxygen content in the water.
An ion meter is used to measure the concentration of ions in a solution.
The Karl Fischer Moisture Analyzer calculates the water content of the sample by calculating the reagent consumption.
Potential Titrator can used for acid-base titration, redox titration.
A turbidity meter is used to measure the degree of turbidity of the water.
pH Meter
PHSJ-3F
- pH Range (-2.00~20.00)
- mV Range (-1999~1999)
- Temperature Range (-5.0~135.0)℃
- pH Resolution 0.01pH
- mV Resolution 1mV
- Temp. Resolution 0.1℃
PHS-2F
- pH Range (0.00~14.00)
- mV Range (-1400~1400)
- pH Resolution 0.01pH
- mV Resolution 1mV
PHS-3E
- pH Range (0.00~14.00)
- mV Range (-1999~1999)
- Temp. Range (0.0~99.9)℃
- pH Resolution 0.01pH
- mV Resolution 1mV
- Temp. Resolution 0.1℃
PHS-3C
- pH Range (0.00~14.00)
- mV Range (-1999~1999)
- pH Resolution 0.01pH
- mV Resolution 1mV
PHB-4
- pH Range ( 0.00~14.00 )
- mV Range ( -1400~1400)
- pH Resolution 0.01 pH
- mV Resolution 1 Mv
Conductivity Meter
DDSJ-308F
- Conductivity Range 0.000μS/cm~199.9mS/cm
- Resistivity Range 5.00Ω·cm~20.00MΩ·cm
- TDS Range 0.000mg/L~1000g/L
- Salinity Range (0.00~8.00)%
- Temperature (-5.0~110.0)℃
DDS-307A
- Conductivity Range 0.00μS/cm~100mS/cm
- TDS Range (0.000~1999) mg/L
- Temperature Range (0.0~99.9)℃
DDS-307
- Conductivity Range 0.00μS/cm~100mS/cm
- Conductivity Error ±1.0%FS
- Calibration 1 point
DDB-303A
- Conductivity Range 0.00μS/cm~100mS/cm
- Conductivity Accuracy ±1.0%FS
- Calibration 1 point
Ion meter
PXSJ-216F
- pH Range (-2.000~20.000)
- pX Range (0.000~14.000)
- mV Range (-1999.9~1999.9)
- Ion Range (0~19990)
- Temp. Range(-5.0~110.0)℃
- pH/pX Resolution 0.001
- mV Resolution 0.1mV
- Ion Resolution 4 significant figures
- Temp. Resolution 0.1℃
Dissolved Oxygen Meter
JPSJ-605F
- DO Range (0.00~20.00)mg/L
- DO Saturation Range (0.0~300.0)%
- Temperature Range (-5.0~110.0)℃
- DO Resolution 0.01mg/L
- DO Resolution Saturation 0.1%
- Temp. Resolution 0.1℃
Turbidity Meter
WZB-170
- Range (0~20.00)NTU, (20.0~200.0)NTU,
- Repeatability ±1.0%
- Zero Drift ±0.5% FS/30min
- Stability ±1.0% FS/30min
- Calibration Up to 3 points
- Sample volume 15mL
- Sample cell size Two,25mmφ*60mm
- IP Grade IP 65
Potential Titrator
ZD-2
- mV Range (0~±1400) mV,
- pH Range(0~14.00)
- Resolution 1mV/0.01pH
- pH basic error ±0.03pH
- mV basic error ±5mV
- Stability ±0.01pH/3h
ZDJ-4B
- Automatic Potential Titrator
- mV Range (-1800.0~1800.0)
- pH Range (0.00~14.00) pH
- Resolution 0.1mV/0.01pH
- pH Basic error ±0.01pH
- mV Basic error ±0.03%FS
- Stability (±0.3mV±1bit)/3h
ZDJ-5B
- mV Range (-1999.0~1999.0)
- pH Range (0.00~14.00)
- Resolution 0.1mV/0.01pH
- pH Basic error ±0.01pH
- mV Basic error ±0.03%FS
- Stability (±0.3mV±1bit)/3h
Karl Fischer Moisture Analyzer
ZDY-502
- Range 0.1mg~250mg
- Resolution 0.1mg
- Accuracy of Polarization Current 1μA±0.2μA/50μA±10μA;
- Repeatability of Titration Analysis ±0.5%