If your lab is focused on water quality analysis, then you will need many electrochemical instruments.

The pH meter helps you detect the pH of the solution.

A conductivity meter is used to estimate the total or salt content of ions in water.

The dissolved oxygen meter is used to measure the oxygen content in the water.

An ion meter is used to measure the concentration of ions in a solution.

The Karl Fischer Moisture Analyzer calculates the water content of the sample by calculating the reagent consumption.

Potential Titrator can used for acid-base titration, redox titration.

A turbidity meter is used to measure the degree of turbidity of the water.

[ultimate_spacer height=”30″]

pH Meter

[ultimate_heading main_heading=”PHSJ-3F” alignment=”left”]

  • pH Range (-2.00~20.00)
  • mV Range (-1999~1999)
  • Temperature Range (-5.0~135.0)℃
  • pH Resolution 0.01pH
  • mV Resolution 1mV
  • Temp. Resolution 0.1℃

[/ultimate_heading]

[ultimate_heading main_heading=”PHS-2F” alignment=”left”]

  • pH Range (0.00~14.00)
  • mV Range (-1400~1400)
  • pH Resolution 0.01pH
  • mV Resolution 1mV

[/ultimate_heading]

[ultimate_heading main_heading=”PHS-3E” alignment=”left”]

  • pH Range (0.00~14.00)
  • mV Range (-1999~1999)
  • Temp. Range (0.0~99.9)℃
  • pH Resolution 0.01pH
  • mV Resolution 1mV
  • Temp. Resolution 0.1℃

[/ultimate_heading]

[ultimate_heading main_heading=”PHS-3C” alignment=”left”]

  • pH Range (0.00~14.00)
  • mV Range (-1999~1999)
  • pH Resolution 0.01pH
  • mV Resolution 1mV

[/ultimate_heading]

[ultimate_heading main_heading=”PHB-4″ alignment=”left”]

  • pH Range ( 0.00~14.00 )
  • mV Range ( -1400~1400)
  • pH Resolution 0.01 pH
  • mV Resolution 1 Mv

[/ultimate_heading]

Conductivity Meter

[ultimate_heading main_heading=”DDSJ-308F” alignment=”left”]

  • Conductivity Range 0.000μS/cm~199.9mS/cm
  • Resistivity Range 5.00Ω·cm~20.00MΩ·cm
  • TDS Range 0.000mg/L~1000g/L
  • Salinity Range (0.00~8.00)%
  • Temperature (-5.0~110.0)℃

[/ultimate_heading]

[ultimate_heading main_heading=”DDS-307A” alignment=”left”]

  • Conductivity Range 0.00μS/cm~100mS/cm
  • TDS Range (0.000~1999) mg/L
  • Temperature Range (0.0~99.9)℃

[/ultimate_heading]

[ultimate_heading main_heading=”DDS-307″ alignment=”left”]

  • Conductivity Range 0.00μS/cm~100mS/cm
  • Conductivity Error ±1.0%FS
  • Calibration 1 point

[/ultimate_heading]

[ultimate_heading main_heading=”DDB-303A” alignment=”left”]

  • Conductivity Range 0.00μS/cm~100mS/cm
  • Conductivity Accuracy ±1.0%FS
  • Calibration 1 point

[/ultimate_heading]

Ion meter

[ultimate_heading main_heading=”PXSJ-216F” alignment=”left”]

  • pH Range (-2.000~20.000)
  • pX Range (0.000~14.000)
  • mV Range (-1999.9~1999.9)
  • Ion Range (0~19990)
  • Temp. Range(-5.0~110.0)℃
  • pH/pX Resolution 0.001
  • mV Resolution 0.1mV
  • Ion Resolution 4 significant figures
  • Temp. Resolution 0.1℃

[/ultimate_heading]

Dissolved Oxygen Meter

[ultimate_heading main_heading=”JPSJ-605F” alignment=”left”]

  • DO Range (0.00~20.00)mg/L
  • DO Saturation Range (0.0~300.0)%
  • Temperature Range (-5.0~110.0)℃
  • DO Resolution 0.01mg/L
  • DO Resolution Saturation 0.1%
  • Temp. Resolution 0.1℃

[/ultimate_heading]

Turbidity Meter

[ultimate_heading main_heading=”WZB-170″ alignment=”left”]

  • Range (0~20.00)NTU, (20.0~200.0)NTU,
  • Repeatability ±1.0%
  • Zero Drift ±0.5% FS/30min
  • Stability ±1.0% FS/30min
  • Calibration Up to 3 points
  • Sample volume 15mL
  • Sample cell size Two,25mmφ*60mm
  • IP Grade IP 65

[/ultimate_heading]

Potential Titrator

[ultimate_heading main_heading=”ZD-2″ alignment=”left”]

  • mV Range (0~±1400) mV,
  • pH Range(0~14.00)
  • Resolution 1mV/0.01pH
  • pH basic error ±0.03pH
  • mV basic error ±5mV
  • Stability ±0.01pH/3h

[/ultimate_heading]

[ultimate_heading main_heading=”ZDJ-4B” alignment=”left”]

  • Automatic Potential Titrator
  • mV Range (-1800.0~1800.0)
  • pH Range (0.00~14.00) pH
  • Resolution 0.1mV/0.01pH
  • pH Basic error ±0.01pH
  • mV Basic error ±0.03%FS
  • Stability (±0.3mV±1bit)/3h

[/ultimate_heading]

[ultimate_heading main_heading=”ZDJ-5B” alignment=”left”]

  • mV Range (-1999.0~1999.0)
  • pH Range (0.00~14.00)
  • Resolution 0.1mV/0.01pH
  • pH Basic error ±0.01pH
  • mV Basic error ±0.03%FS
  • Stability (±0.3mV±1bit)/3h

[/ultimate_heading]

Karl Fischer Moisture Analyzer

[ultimate_heading main_heading=”ZDY-502″ alignment=”left”]

  • Range 0.1mg~250mg
  • Resolution 0.1mg
  • Accuracy of Polarization Current 1μA±0.2μA/50μA±10μA;
  • Repeatability of Titration Analysis ±0.5%

[/ultimate_heading]